Hobbe
My feedback
-
155 votes
Hobbe supported this idea ·
-
151 votes
Hobbe supported this idea ·
-
185 votesEVALUATING · 1 comment · PI Server » Analytics & Calculations · Flag idea as inappropriate… · Admin →
Hobbe supported this idea ·
-
214 votes
We are working to introduce filtering and sorting to the Management tab, along with other features.
Hobbe supported this idea ·
-
5 votes
Hobbe supported this idea ·
-
102 votes
This feedback item has been moved from the PI Connectors forum to the PI Adapters forum.
We are continuing to support the PI Connector for OPC UA with stability and security releases. However, for feature enhancements, we are considering them for the PI Adapter for OPC UA. We would like to hear more about your use cases for this functionality, so please share with us in the comments.
An error occurred while saving the comment An error occurred while saving the comment Hobbe commented
Hi!
Currently we are using OPC AE and storing the events in Event Frames. When we move to use OPC UA we need to start to work with Alarms & Conditions instead!
Also i want a way to native create Event Frames within the Connector for OPC UA.
//MagnusAn error occurred while saving the comment Hobbe commented
Hi! We are about to do a pilot with alarms and events to let them be stored into event frames!
I heared it was a new product from OSI regarding this issue! We want to be involved in a Beta test.
We use Siemens WinCC and ABB 800 xA DCS systems.//Magnus Holmbom, Vattenfall Vattenkraft AB
Hobbe supported this idea ·
-
3 votes
Hobbe shared this idea ·
-
210 votes
With the introduction of CoreWCF 1.0, we are re-evaluating this request. Performance, backwards compatibility, security, and technological longevity are key features that we are researching.
Please continue to share your use cases with us, as well as any key capabilities that your use case requires.
Hobbe supported this idea ·
-
333 votes
Reopening this suggestion to collect additional feedback.
An error occurred while saving the comment Hobbe commented
Hi!
We want to be able to execute Python scripts from AF analyses.
Hobbe supported this idea ·
-
4 votes
An error occurred while saving the comment Hobbe commented
I use a JSON formatted payload
{
"code":"request",
"cid":4747,
"adr":"/getdatamulti",
"data":{"datatosend":[
"processdatamaster/temperature",
"devicetag/applicationtag",
"iolinkmaster/port[1]/mode",
"iolinkmaster/port[1]/comspeed",
"iolinkmaster/port[1]/pin2in",
"iolinkmaster/port[1]/iolinkdevice/vendorid",
"iolinkmaster/port[1]/iolinkdevice/deviceid",
"iolinkmaster/port[1]/iolinkdevice/applicationspecifictag",
"iolinkmaster/port[1]/iolinkdevice/pdin",
"iolinkmaster/port[1]/iolinkdevice/status",
"iolinkmaster/port[1]/iolinkdevice/productname",
"iolinkmaster/port[1]/iolinkdevice/serial",
"iolinkmaster/port[2]/mode",
"iolinkmaster/port[2]/comspeed",
"iolinkmaster/port[2]/pin2in",
"iolinkmaster/port[2]/iolinkdevice/vendorid",
"iolinkmaster/port[2]/iolinkdevice/deviceid",
"iolinkmaster/port[2]/iolinkdevice/applicationspecifictag",
"iolinkmaster/port[2]/iolinkdevice/pdin",
"iolinkmaster/port[2]/iolinkdevice/status",
"iolinkmaster/port[2]/iolinkdevice/productname",
"iolinkmaster/port[2]/iolinkdevice/serial"
]
}
}respons:
{"cid":4747,"data":{"processdatamaster/temperature":{"code":200,"data":30},"devicetag/applicationtag":{"code":200,"data":"AL1350"},"iolinkmaster/port[1]/mode":{"code":200,"data":3},"iolinkmaster/port[1]/comspeed":{"code":200,"data":1},"iolinkmaster/port[1]/pin2in":{"code":200,"data":0},"iolinkmaster/port[1]/iolinkdevice/vendorid":{"code":200,"data":310},"iolinkmaster/port[1]/iolinkdevice/deviceid":{"code":200,"data":733},"iolinkmaster/port[1]/iolinkdevice/applicationspecifictag":{"code":200,"data":"***"},"iolinkmaster/port[1]/iolinkdevice/pdin":{"code":200,"data":"00F3FF00"},"iolinkmaster/port[1]/iolinkdevice/status":{"code":200,"data":2},"iolinkmaster/port[1]/iolinkdevice/productname":{"code":200,"data":"TV7105"},"iolinkmaster/port[1]/iolinkdevice/serial":{"code":200,"data":"000079227024"},"iolinkmaster/port[2]/mode":{"code":200,"data":3},"iolinkmaster/port[2]/comspeed":{"code":503},"iolinkmaster/port[2]/pin2in":{"code":200,"data":0},"iolinkmaster/port[2]/iolinkdevice/vendorid":{"code":503},"iolinkmaster/port[2]/iolinkdevice/deviceid":{"code":503},"iolinkmaster/port[2]/iolinkdevice/applicationspecifictag":{"code":503},"iolinkmaster/port[2]/iolinkdevice/pdin":{"code":503},"iolinkmaster/port[2]/iolinkdevice/status":{"code":200,"data":0},"iolinkmaster/port[2]/iolinkdevice/productname":{"code":503},"iolinkmaster/port[2]/iolinkdevice/serial":{"code":503}},"code":200}
Hobbe shared this idea ·
-
11 votes
Hobbe supported this idea ·
-
23 votes
Hobbe supported this idea ·
-
111 votes
Hobbe supported this idea ·
-
13 votes
Hobbe supported this idea ·
-
10 votes
Hobbe supported this idea ·
-
3 votes
Hobbe supported this idea ·
-
12 votes
Hobbe supported this idea ·
-
71 votes
Hobbe supported this idea ·
-
41 votes
An error occurred while saving the comment Hobbe commented
Hi! This is a must to have feature! If you want to display KPI´s that of coarse are based uppon caledar time this is a must to have!
Hobbe supported this idea ·
-
143 votes
Hobbe supported this idea ·
What is your primary use case for collecting A&C data?
We use the A&C data for troubleshooting, root case analyses and continous improvements!
o How do you collect A&C data today?
We use the OPC AE Interface.
o How is their A&C data stored in PI?
We are currently investigating if we can store it in event frames.
o What sort of alarm data do you have? I.e. instantaneous alarms, acknowledgements, alarms with a start and stop time?
We have all of the above alarms!
o What is the preferable way to create Alarms and Conditions within PI (i.e. PI Tags, Event Frames, etc.)
Preferably it has to be stored in a relational database, maybe as Event frames. I think if the adapter can create event frames would be the best!
o What is your best estimate for how many alarms/events should be created in a year?
We have 10.000.000 events per year and rising!
o What do you use to consume A&C data? How do you utilize A&C data afterwards?
We use it when a failure occurs in our plants for trouble shooting and root cause analyses. We also plan to use it as reports!
o How do you visualize A&C data?
We are trying out PI Vision Events list but are not really satisfied with the performance and flexibility.
Also reports can be created in Power BI using the integrator for BI.