    FranzK commented  · 

    Meanwhile it would be great to get an whitepaper how to manually rollback a wrong configured connector . unfortunately it's very easy, to do a wrong configuration (e.g. include all PI Tags from PI Server, forget to set a prefix,...) or an typo occurs during configuration. It would be very bad to have "dead configurations" in the System or need to setup the whole system again.

    FranzK supported this idea  · 
  2. 8 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    FranzK supported this idea  · 
  3. 49 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    4 comments  ·  PI Server » Analytics & Calculations  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK supported this idea  · 
  4. 207 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    12 comments  ·  PI Vision » Ad Hoc Analysis  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK supported this idea  · 
  5. 20 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Vision » Security  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK supported this idea  · 
  6. 14 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Vision » Search  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK supported this idea  · 
  7. 5 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Vision » Administration  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK supported this idea  · 
  8. 5 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Vision » Events (EF)  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK supported this idea  · 
  9. 2 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Vision » Bugs *PLEASE SEND TO TECH SUPPORT*  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK commented  · 

    this Looks more like a bug. did you open an Support request?

    FranzK supported this idea  · 
  10. 3 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Vision » Event Comparison Displays  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK supported this idea  · 
  11. 3 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Connectors » Other specific PI Connector  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK commented  · 

    it's very important to get all needed information from the PCS 7 Alarm System - also for multi level alarms (so for example have a child event frame for warning low, alarm low low, warning low of a single pcs7 block with different alarm levels).

    FranzK supported this idea  · 
  12. 122 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    12 comments  ·  PI Connectors » General  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK supported this idea  · 
  13. 54 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Server » Data Archive  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK commented  · 

    to use these information, i see these possibilities:

    - get a report to see what data to delete.
    - get notifications
    - have a user-interface which supports the process of deleting data (e.g. also enter information shown in audit- trail).
    - for some tags it might be useful the data get deleted automatically.

    FranzK supported this idea  · 
  14. 107 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    13 comments  ·  PI Server » Analytics & Calculations  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK commented  · 

    when developing this solution, please also keep in mind the following post:
    https://feedback.osisoft.com/forums/555148-pi-server/suggestions/32194798-event-frame-ef-linking

    it's important to define the child event frames as flexible as possible (e.g. also from a different AF Database,..).

    FranzK supported this idea  · 
  15. 169 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    20 comments  ·  PI Vision » Sharing & Collaboration  ·  Flag idea as inappropriate…  ·  Admin →
    PLANNED  ·  Alicia Coppock responded

    The export of displays to a file so that they can be imported to another PI Vision server is planned for the PI Vision 4.x release.

    FranzK commented  · 

    is this a similar topic?
    https://feedback.osisoft.com/forums/320517-pi-vision/suggestions/18689953-exporting-and-importing-of-displays

    important is also how the requirement is implemented - e.g. what does the export-file look like? what data format is used - am i able to edit these files.

    FranzK supported this idea  · 
  16. 124 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    15 comments  ·  PI Vision » Manual Data Entry  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK commented  · 

    will there also be the possibility to configure 21-cfr support (electronic signature)?

    FranzK supported this idea  · 
    FranzK commented  · 

    i saw more post with different wording for the same topic. OSISoft should think about managing feedback (e.g. merge similar topics). all in all i think Manual Data Entry already has more than 100 votes!

    FranzK commented  · 

    custom symbols is under full support. so it's hard to use in a regulated environment (e.g. pharmaceutical industries). it would also be great to get the possibility to configure electronic signature (FDA Part11) for the symbol (configure, so it's possible to activate if needed).

  17. 56 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    3 comments  ·  PI Vision » Display Management / Displays Page  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK commented  · 

    it should be possible to get also the information what changed from version to version (e.g. symbol ... added to the display, symbol ... color changed from red to green). or at least it should be possible to enter this information manual.

    FranzK supported this idea  · 
  18. 11 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    4 comments  ·  PI Vision » Event Comparison Displays  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK commented  · 

    Hi Victor, i suggest it should be possible to configure the behavior. i would personally assign color by attribute and distinguish the batches by line style and or line weight. but others might prefer to distinguish by color. this configuration should be possible on display level.
    there should also be other possibilities for overlay trend like, arrange them free on the display, add multiple y-scales and configure these scales flexible.

    FranzK supported this idea  · 
  19. 15 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    7 comments  ·  PI Vision » Manual Data Entry  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK commented  · 

    regarding this it should also be possible to configure if a Comment/Reason code is required before Acknowledging an Event - as this might also impact other applications, a solution might be implemented on AF/EF level.

    FranzK commented  · 

    There is also a need to comment on PI Tag values with electronic signature!!!

    FranzK commented  · 

    that would be great. for processbook we had to program an own plug in. hope in coresight this comes out of the box.

    FranzK supported this idea  · 
  20. 3 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Server » Event Frames (EF)  ·  Flag idea as inappropriate…  ·  Admin →
    FranzK shared this idea  · 
← Previous 1 3 4

Feedback and Knowledge Base

Posted ideas will have one of the following statuses.
Full definition of these statuses can be found on the Home Page.
No status
NEEDS MORE DISCUSSION
RESEARCHING/EVALUATING
DECLINED
PLANNED
STARTED/IN DEVELOPMENT
IN BETA
COMPLETED