    Gabriel Michaud-Verreault commented  · 

    The current workaround would be to get the status using a REST call, and then store the result:
    https://<connectorNode>:<port>/admin/api/instrumentation/Failover%20Status
    The result of the REST call, would be a JSON containing the information for both members. This could be stored in PI simply using PowerShell or the PI Connector for UFL.

  2. 4 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Connectors » OPC UA  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault commented  · 

    The connector follow the OPC Foundation specifications. As an OPC UA client, all values received from an OPC UA compliant server is to be in UTC. The connector then sends it to PI DA in UTC. Depending on the client tool you are using, you can then retrieve UTC or Local timestamp.

    Please see https://reference.opcfoundation.org/v104/Core/docs/Part3/8.38/
    All time values conveyed between OPC UA Servers and Clients are UTC values. Clients shall provide any conversions between UTC and local time.

  3. 1 vote
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Integrators » PI Integrator for Esri ArcGIS  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault shared this idea  · 
  4. 9 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    3 comments  ·  PI Integrators » PI Integrator for Esri ArcGIS  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault commented  · 

    The person performing the install / upgrade should not necessarily have access to the database, and the DBA should not necessarily have access to the frontend application node.

    Another use case, is when there is simply a move of the application service - no need to change the SQL backend.
    Additionally, all products should be consistent. AF and PI Vision already provide this functionality, it should be standard across all applications with a SQL backend.

    Gabriel Michaud-Verreault supported this idea  · 
  5. 10 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    3 comments  ·  PI Connectors » OPC UA  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault commented  · 

    There should be a way to better handle infrequently changing values, but Trend Advise should not be the implementation. Trend Advise is the same as changing the PI Point to STEP=ON. Trend Advise stores a value that would not have been actually read from the OPC UA Server and stores the last value right before - this does not only occur when there is a long period of time with no data, it happens for every event, meaning that in practical terms, it becomes a step tag.

  6. 7 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    3 comments  ·  PI Connectors » General  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault commented  · 

    In response to Dan Louchbaum, "For Hi Speed connectors on manufacturing..."
    In my comment about compression, I meant that every event sent by the connector to the relay (this is not a PI Event, an 'event' can contain thousand of data values), are compressed (file compressed), so it would limit the bandwidth usage between the 2 components

    Gabriel Michaud-Verreault commented  · 

    PI Connectors with the relay configuration (2.x) compress the data before sending it to the relay which would allow for a reduction of network traffic

  7. 9 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Connectors » OPC UA  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
  8. 1 vote
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Connectors » Other specific PI Connector  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault shared this idea  · 
  9. 3 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Connectors » OPC UA  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
  10. 4 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Connectors » New PI Connector request  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
    Gabriel Michaud-Verreault commented  · 

    One could use the OPC UA Connector since TwinCat it already comes with an OPC UA Server. It is also their recommended data access tool to get data out.

  11. 1 vote
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Connectors » Wonderware Historian  ·  Flag idea as inappropriate…  ·  Admin →
  12. 12 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    2 comments  ·  PI Connectors » New PI Connector request  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
  13. 15 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    2 comments  ·  PI Connectors » Wonderware Historian  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
  14. 28 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    4 comments  ·  PI Connectors » OPC UA  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault commented  · 

    This can be achieved by setting UseDnsNameAndPortFromDiscoveryUrl = False in App.OpcUa.Config and restarting the connector for the changes to take effect.

    Gabriel Michaud-Verreault commented  · 

    Example of the implementation in UAExpert attached.

    Article describing this more in depth
    https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=OPC-UA-Cannot-connect-when-using-IP-Address

    Gabriel Michaud-Verreault supported this idea  · 
  15. 3 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Connectors » New PI Connector request  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
  16. 15 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Connectors » UFL  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
  17. 16 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Connectors » General  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
  18. 3 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Connectors » UFL  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
  19. 7 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Connectors » PI System Connector  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
  20. 5 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Connectors » BACnet  ·  Flag idea as inappropriate…  ·  Admin →
    Gabriel Michaud-Verreault supported this idea  · 
← Previous 1 3 4 5 6

Feedback and Knowledge Base

Posted ideas will have one of the following statuses.
Full definition of these statuses can be found on the Home Page.
No status
NEEDS MORE DISCUSSION
RESEARCHING/EVALUATING
DECLINED
PLANNED
STARTED/IN DEVELOPMENT
IN BETA
COMPLETED