    Lok Shun Ko commented  · 

    Note: Built-in portal accounts will continue to work to create layers through the PI Integrator if they remain enabled on a SAML-enabled portal. However, it will not be possible to create augmented feature layers at all.

  2. 79 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    4 comments  ·  PI Server » Analytics & Calculations  ·  Flag idea as inappropriate…  ·  Admin →
    Lok Shun Ko supported this idea  · 
  3. 1 vote
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  PI Integrators » General  ·  Flag idea as inappropriate…  ·  Admin →
    Lok Shun Ko shared this idea  · 
  4. 15 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    Lok Shun Ko commented  · 

    Use cases:
    1) It's not uncommon for analyses to be triggered and close event frames several minutes into the past. Lab values that are entered manually are one example. Refer to case 900272.

    2) Mobile assets often have limited connectivity to send data to the PI System. Often times, they will lose connection for 2-3 hours, and finally update data when arriving back to home base. These event frames are backfilled into the PI AF Server by PI Analysis, but do not get published by the PI Integrator

    Lok Shun Ko shared this idea  · 
  5. 16 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Integrators » General  ·  Flag idea as inappropriate…  ·  Admin →
    Lok Shun Ko commented  · 

    On top of annotations, several other extended properties of the event frame could be valuable for companies working more extensively with event frame acknowledgements.
    Event frame severity, is acknowledged, acknowledged by, acknowledged date.

  6. 8 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    1 comment  ·  PI Vision » Manual Data Entry  ·  Flag idea as inappropriate…  ·  Admin →
    Lok Shun Ko commented  · 

    Here is a configuration you can use to hide the conditional tag. In this case, it's BA:ACTIVE.1

    The CMDE:
    if(LastArchiveValue("BA:ACTIVE.1")==DigCode("Inactive","BA:ACTIVE.1"),CollectNow(),Skip())
     
    To hide BA:ACTIVE.1:
    if(IsUnknown(CurrentValue("BA:ACTIVE.1")),Skip(),Skip())

  7. 18 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  NOC Services  ·  Flag idea as inappropriate…  ·  Admin →
    Lok Shun Ko supported this idea  · 
  8. 19 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  NOC Services  ·  Flag idea as inappropriate…  ·  Admin →
    Lok Shun Ko supported this idea  · 
  9. 6 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  NOC Services  ·  Flag idea as inappropriate…  ·  Admin →
    Lok Shun Ko supported this idea  · 
  10. 7 votes
    Sign in Sign in with OSIsoft
    Signed in as (Sign out)

    We’ll send you updates on this idea

    0 comments  ·  NOC Services  ·  Flag idea as inappropriate…  ·  Admin →
    Lok Shun Ko supported this idea  · 

Feedback and Knowledge Base

Posted ideas will have one of the following statuses.
Full definition of these statuses can be found on the Home Page.
No status
NEEDS MORE DISCUSSION
RESEARCHING/EVALUATING
DECLINED
PLANNED
STARTED/IN DEVELOPMENT
IN BETA
COMPLETED